LNG IWT Project Database

Installations and Equipment for LNG – Design of Onshore Installations with a Storage Capacity between 5 t and 200 t (EN 13645)

Type of project

StudyRegulationGuideline/StandardPlatformFundingImplementation

Place in LNG chain

SupplyStorageDistributionLNG as CargoBunkeringLNG as Fuel

IWT Corridor

Belgian & Dutch Inland WaterwaysDanube & MainElbe & Northern German Inland WaterwaysPoRhineRhone & SaoneSeine & Northern FranceThamesOther Inland Waterway/Not definedMaritime (IWT-relevant)Wadden Sea

Project status

Completed

Year of project completion

2001

Number of ships

Port

Project partners

European Committee for Standardization (CEN)

Countries

  • Albania
  • Bosnia and Herzegovina
  • Bulgaria
  • Croatia
  • Cyprus
  • Czech Republic
  • Denmark
  • Estonia
  • Finland
  • France
  • Germany
  • Greece
  • Hungary
  • Iceland
  • Ireland
  • Italy
  • Latvia
  • Lithuania
  • Luxembourg
  • Malta
  • Montenegro
  • Netherlands
  • Norway
  • Poland
  • Portugal
  • Romania
  • Serbia
  • Slovakia
  • Slovenia
  • Spain
  • Sweden
  • Switzerland
  • Turkey
  • United Kingdom
  • FYR Macedonia

Study to download

Technical data

Notes/comments

This European Standard specifies requirements for the design and construction of onshore stationary liquefied natural gas (LNG) installations with a total storage capacity between 5 t and 200 t. This standard is not applicable to liquefaction process facilities based on hydrocarbon refrigerants. Larger installations are treated according to EN 1473:1997. If other dangerous substances are present in the facility, the aforementioned storage capacity thresholds may be reduced. NOTE It is essential that the designer refer to local regulation to determine the new values. The installations to which this standard is applicable include the following: - LNG satellite plants. The LNG may be supplied by road tankers, barge or rail carriers. After storage, LNG is vaporized and sent out to consumers

- LNG gas fuelling stations for vehicles. The installation is limited from the gas inlet or the loading LNG area to the gas outlet or the unloading LNG area. Filling systems are not covered here. For the purposes of clause 4 «Environment Impact» and clause 5 «Safety Plan», this standard applies where LNG storage capacity exceeds the threshold specified in the local regulation. If this value is not available, a threshold of 50 t is recommended. It is recalled that, in any case, local regulations prevail. For the purposes of clause 4 «Environment Impact» and clause 5 «Safety Plan», this standard applies where LNG storage capacity exceeds the threshold specified in the local regulation. If this value is not available, a threshold of 50 t is recommended. It is recalled that, in any case, local regulations prevail. (Source: CEN website, see link above)